Susol VCB for Special Purpose

LS ELECTRIC provides various solutions for nuclear power plants, generators, compact panels, and retrofits

Features

Susol VCB for Nuclear power plants

Product Overview

Susol VCB satisfies quality, safety measures (secure from earthquakes and other natural disasters), and surge protection class that complies with “1E-CLASS” ±provisions. It features a high-breaking technology, safety, and reliability by applying our own vacuum interrupters (59kA) approved by ANSI standard tests.

Benefits
  • Full option provided to prevent fatal error, property loss, and death caused by operator error
  • Bushing applied for window CT adaptation
  • Satisfies earthquake and other internal environment specifications
Main specification
  • Ratings : up to 15kV 50kA 3000A
  • Rated short time withstand current: 3sec
  • Rated operating sequence : O-0.3s-CO-3min-CO
  • Standards : ANSI/IEEE Std. C37.09 , KEPIC EED 1100

Susol VCB for Generator

Product Overview

VCB for generator can be installed between the generator and TR. The breaker opens and closes the load current and protects the system by branching the circuit in the event of an accident on the primary and secondary sides.

Benefits
  • Solution for renewable energy power plants, networks with emergency power generator, and retrofit for hydro and cogeneration
  • Various accessories provided to prevent fatal errors, property loss, and death caused from operator during operations.
Main specification
  • Ratings : up to 17.5kV 50kA 5000A
  • Rated short time withstand current: 50kA/4sec
  • Rated operating sequence : CO-30min-CO (short circuit), O-3min-CO-3min-CO (Load switching)
  • Out-of-phase(OP1&OP2): 17.5kV 25kA
  • Standards : IEC/IEEE 62271-37-013 for generator circuit breaker

Susol Side mount VCB

Product Overview

SM VCB series are side mounted products featuring a main structure compact in size, highly reliable, and allows for a variety of accessories to be installed in the compact panel such as C-AIS.

Benefits
  • Solutions for compact panel, AIS through side mounted structure and compact size
  • Maximized compatibility for panel makers by providing various phases and terminal options
Main specification
  • Ratings : up to 25.8kV 25kA 1250A
  • Rated short time withstand current: 4sec
  • Rated operating sequence : O-0.3s-CO-15s-CO
  • Standards : IEC62271-100 [M2,C2,E2]

Susol Retrofit VCB

Product Overview

Retofit VCB replaces old VCBs installed and operated in switchboards without changing bus-bars and control circuits to maintain system stability with minimal time and cost.

Benefits

LS ELECTRIC provides total solutions such as control circuit inspection and parts replacement

Without replacing the bus-bar, 1: 1 compatibility with the cradle reduces replacement time

Provides high capacity and high blocking performance by minimizing bus processing costs

Specification

All in one

Hanoi Office

10th floor, 789 building, 147 Hoang Quoc Viet street, Cau Giay District, Ha Noi city, Vietnam

Hai Phong

LGE Factory - Tràng Duệ Industrial - An Dương District, Hải Phòng City

Da Nang

Văn phòng đối tác (HVN) 305 - Nguyễn Tất Thành - Hải Châu - Đà Nẵng

Ho Chi Minh Office

17th floor, Empress building, 138-142 Hai Ba Trung street, Da Kao ward, Distric 1, Ho Chi Minh city, Vietnam