Use conditions | Control method | PWM controlled sine wave current driving method |
---|
Operatingtemperature/storagetemperature | 0∼+40[℃] / -20~ +60[℃] |
---|
Operatinghumidity/storagehumidity | Below 80% RH / Below 90% RH (no freeze or condensation) |
---|
Vibration-/impact-resistance | TBD |
---|
Degreeofprotection/degreeofpollution | TBD |
---|
Altitude | 1000m or lower |
---|
Other | To be free from electrostatic noise, strong electrolysis, or radiation. |
---|
Performance | Speed variation | Load variation | At 0 to 100% load: ± 3% (at rated speed) |
---|
Voltage variation | Rated voltage ±10%: 0% (at rated speed) |
---|
Temperaturevariation | 25℃: ±0.1% or less (at rated speed) |
---|
Input/output signal | Input signal | Input voltage range: DC 12 V - DC 30 V |
---|
The 4-channel input signal can be assigned to 12 functions: |
POT, NOT, HOME, STOP, PCON, GAIN2, PCL, NCL, PROBE1, PROB2, EMG, and ARST. |
Output signal | Rated voltage and current: DC 24 V ±10%, 120 [ ] |
---|
The 2-channel output signal can be assigned to 11 functions: BRAKE, ALARM, RDY, ZSPD, INPOS1, TLMT, VLMT, INSPD, WARN, TGON, and INPOS2. |
Analog Monitor | Number of channels: 1, Output voltage range: ±4V, Angular resolution: 12 bits, Stabilization time: 15 us |
---|
USB communication | Connecting device | PC or USB storage medium |
---|
Communication standard | Conform to the USB 2.0 Full Speed Standard. |
---|
Function | Firmware download, parameter setting, adjustment, auxiliary functions, and parameter copy function. |
---|
Dynamic brake (three-phase short-circuit) | Activates when servo alarm, servo OFF, or Emergency stop (POT, NOT and EMG) is input. |
---|
Protection functions | Overcurrent, overload, current limit, overheat, overvoltage, undervoltage, overspeed, encoder error, position follow error, ect. |
---|
Auxiliary functions | Gain adjustment, alarm history, JOG drive, programmed JOG drive, etc. |
---|
Safety functions | Input | STO1 and STO2 |
---|
Compatible standard | TBD |
---|