iP5A

Fan and Pump Drive​

Features

Dual PID

When additional PID control or cascade PID control is required, dual PID provide users with various uses of the system with only iP5A.

Multi Motor Control

The built-in algebra control function enables an inverter to control motors without a controller so that user can take advantage of energy-saving and lower costs.

Sleep and Wake-Up

The built-in energy saving function makes the inverter stop automatically when the capacity is too low.

Pre-Heater

The built-in pre-heater function prevents motor damage and inverter break-down caused from humidity.

Flying Start

When the inverter drives many ventilators or when the fan in a big load system turns due to a natural displacement, iP5A operates the motor by automatically searching for the motor speed.

Auto energy saving

iP5A provides the auto energy saving function by an optimal flux control which minimizes energy loss caused by load change.

Improved Management from Instant Power-off and Power Dip Generation

During the power dip or instant power-off, which is generated by lightening, ground fault, and power-failure, loads still keep the mechanical energy and this energy flows back to inverter by regeneration. The power-failure guarantee time is extended by using this electrical character of the inverter.

Constant and Stable Performance (24 hours 365 days)

Regardless of outside alteration such as input voltage variation by load change or weather effect, iP5A can handle motor and load with best performance.

Safety Stop

When unexpected power-failure blocks the power supply, the inverter stops the motor by using energy of the load that prevents reoccurrence of accidents  (Parameter setting is required).

Type Designation

Specification

3-phase 200V Class (0.75~30kW)
Model Number (SVㅁㅁㅁiP5A-2)008015022037055075110150185220300
Capacity [kVA] 1)1.93.04.66.16.112.217.522.928.233.543.8
Output
ratings
Fan or
pump load
Motor rating 2)(HP)12357.5101520253040
(kW)0.751.52.23.75.57.5111518.52230
Current [A]581216243246607488115
(110% over current)110% 1 Minute (Normal Duty)
General
load
Motor rating(HP)0.512357.51015202530
(kW)0.40.751.52.23.75.57.5111518.522
Current [A]2.5581217233344546884
(150% over current)150% 1 Minute (Heavy Duty)
Frequency0.01~120 Hz
Voltage200~230V 3)
Input
ratings
Voltage3Ø200~230V (-15%~+10%)
Frequency50/60 Hz (± 5%)
Protection degreeIP20 / UL Type1IP00 / UL Open 4)
Weight [kg (lbs.)]4.1
(9.0)
4.2
(9.3)
4.2
(9.3)
4.9
(10.8)
4.9
(10.8)
6
(13.2)
6
(13.2)
13
(28.7)
13.5
(29.8)
20
(44.1)
20
(44,1)
3-phase 400V Class (0.75~90kW)
Model Number (SVㅁㅁㅁiP5A-4)008015022037055075110150185220300370450550750900
Capacity [kVA] 1)2.03.24.86.49.612.719.123.931.135.948.659.872.587.6121.1145.8
Output
ratings
Fan or
pump load
Motor rating 2)(HP)12357.5101520253040506075100125
(kW)0.751.52.23.75.57.5111518.522303745557590
Current [A]2.5468121624303945617591110152183
(110% over current)110% 1 Minute (Normal Duty)
General
load
Motor rating(HP)0.512357.5101520253040506075100
(kW)0.40.751.52.23.75.57.5111518.5223037455575
Current [A]1.252.5468.8121622/2428/3034/3944/45-----
(150% over current)150% 1 Minute (Heavy Duty)
Frequency0.01~120 Hz
Voltage380~480V 3)
Input
ratings
Voltage3Ø380~480V (-15%~+10%)
Frequency50/60 Hz (± 5%)
Protection degreeIP20 / UL Type1IP00 / UL Open 4)
Weight [kg (lbs.)]Standard Type4.1
(9.0)
4.2
(9.3)
4.2
(9.3)
4.9
(10.8)
4.9
(10.8)
6
(13.2)
6
(13.2)
12.5
(27.6)
13
(28.7)
20
(44.1)
20
(44.1)
27
(59.5)
27
(59.5)
29
(64)
43
(94.8)
42
(92.6)
Built-in DCL Type-------19.5
(43.9)
19.5
(42.9)
26.5
(58.3)
26.5
(58.3)
39
(86)
40
(88.2)
42
(92.6)
67
(147.4)
68
(149.9)
3-phase 400V Class (110~450kW)
Model Number (SVㅁㅁㅁiP5A-2)11001320160022002800315037504500
Capacity [kVA] 1)178210259344436488582699
Output
ratings
Fan or
pump load
Motor rating 2)(HP)150200250350400500600700
(kW)110132160220280315375450
Current [A]223264325432547613731877
(110% over current)110% 1 Minute (Normal Duty)
General
load
Motor rating(HP)125150200250350400500600
(kW)90110132160220280315375
Current [A]183223264325432547613731
(150% over current)150% 1 Minute (Heavy Duty)
Frequency0.01~120 Hz
Voltage380~480V 3)
Input
ratings
Voltage3Ø380~480V (-15%~+10%)
Frequency50/60 Hz (± 5%)
Protection degreeIP00 / UL Open 4)
DCLBuilt-inExternal Option
Weight [kg (lbs.)]101 (222.7)101 (222.7)114 (251.3)200 (441.9)200 (441.9)243 (535.7)380 (837.7)380 (837.7)
3-phase 600V Class (5.5~110kW)
Model Number (SVㅁㅁㅁiP5A-2)0550751101501852203003704505507509001100
Capacity [kVA] 1)9.612.719.123.931.135.948.659.872.587.6121.1145.8178
Output
ratings
Fan or
pump load
Motor rating 2)(HP)7.5101520253040506075100125150
(kW)5.57.5111518.522303745557590110
Current [A]9121723273443556480104128150
(110% over current)110% 1Minute (Normal Duty)
General
load
Motor rating(HP)5.57.5101520253040506075100125
(kW)3.75.57.5111518.522303745557590
Current [A]6.19121723273443556480104128
(150% over current)150% 1 Minute (Heavy Duty)
Frequency0.01~120 Hz
Voltage525 ~600V 3)
Input
ratings
Voltage3f 525~600V (-15% ~ +10 %)
Frequency50/60 Hz (±5 %)
Protection degreeIP20 / UL Type1IP00 / UL Open 4)
Weight [kg (lbs.)]6.5
(14.4)
7.0
(15.5)
7.0
(15.5)
11.7
(25.8)
11.7
(25.8)
18.9
(41.7)
18.9
(41.7)
32
(70.65)
32
(70.65)
32
(70.65)
46
(101.5)
46
(101.5)
101
(223)

1) Rated capacity (v 3 X V X I) is based on 220V for 200V class and 460V for 400V class.
2) Indicates the maximum applicable capacity when using a 4-Pole LS motor.
3) Maximum output voltage will not exceed the input voltage. An output voltage less than the input voltage may be programmed if necessary.
4) IP20/UL Type1 with optional conduit, it can be modified to UL Type-1.

More Information

All in one

Hanoi Office

10th floor, 789 building, 147 Hoang Quoc Viet street, Cau Giay District, Ha Noi city, Vietnam

Hai Phong

LGE Factory - Tràng Duệ Industrial - An Dương District, Hải Phòng City

Da Nang

Văn phòng đối tác (HVN) 305 - Nguyễn Tất Thành - Hải Châu - Đà Nẵng

Ho Chi Minh Office

17th floor, Empress building, 138-142 Hai Ba Trung street, Da Kao ward, Distric 1, Ho Chi Minh city, Vietnam

Log in