iC5 (EOL)

Micro Drive​

Features

  • Sensorless vector control
    The iC5 adopted the sensorless vector control algorithm, which improves not only the torque control characteristics, but the speed controllability in uncertain conditions caused by the load variation.
  • Auto Tuning
    The auto tuning algorithm in the iC5 sets the motor factors automatically that brings the traditional commissioning difficulties mainly in low speed by the load variation and the low torque generation to a settlement.
  • Highly efficient DSP chip
    The iC5 adopts a highly efficient DSP (Digital Signal Processing) chip to improve processing speed, flexibility, and stability.
  • PNP and NPN Dual Control Signal
    The iC5 provides PNP and NPN signals for outside controllers.
    It works with 24Vdc regardless of the type of PLC or control signals.
  • Communication interface, Modbus-RTU
    The iC5 provides the most popular communication interface, ModBus-RTU for remote control by the PLC or other devices.
  • PID Control
    PID process control is used in iC5 to quickly make speed corrections with a minimal amount of overshoot and oscillation for the control of flow, temperature, and pressure.

Type Designation

Specification

200V Class
Specification - 200V Class
Type SV004 iC5-1 SV008 iC5-1 SV015 iC5-1 SV022 iC5-1
200V Class Motor Rating [HP] 0.5 1 2 3
[kW] 0.4 0.75 1.5 2.2
Output ratings Capacity[kVA] 0.95 0.95 3.0 4.5
FLA[A] 2.5 0.95 3.0 4.5
Output frequency 0 ~ 400Hz
Output voltage 3 Phasde200~230V
Input ratings Voltage Single phase 200 ~ 230 V (±10%)
FLA[A] 5.5 9.2 16 21.6
Frequency 50 ~ 60 Hz (± 5%)
Control Control method V/F control, Sersorless vector control
Frequency setting resolution Digital reference: 0.01Hz
Analog referency: 0.06Hz/60Hz
Frequency setting resolution Digital reference: 0.01Hz
Analog referency: 0.06Hz/60Hz
V/F ratio Linear, Square pattern, User V/F
Overload capacity 1 min at 150%, 30 sec at 200% (with inverse characteristic)
Torque boost Manual torque boost (0~15 adjustable), auto torque boost
Input signal Operation method Keypad / Terminal / Communications
Frequency setting Analog: 0~10V / 4~20mA, Digital: Keypad,
Communication: RS485 (Option)
Start signal Forward, Reverse
Multi-step accel/decal time 0.1~6000 sec. Max. 8 types available by multi-function terminal, Selectable accel/decel patterns : Linear, U and S
Emergency stop Interrupting the output of the drive.
Jog Jog operation
Fault reset Reset the fault when protective function is active
Output signal Operation status & fault output Frequency detection, Overload alarm, Stalling, Overvoltage, Undervoltage, Drive overheating, Run, Stop, Constant speed, Speed searching, Fault output ( Relay and Open collector output )
Indicator Choose one from output frequency, current, voltage and DC voltage.(Output voltage : 0~10V )
Operation function DC braking, Frequency limit, Frequency jump, Second function, Slip compensation, Reversing prevention, Auto restart, PID control
Protection functions Drive trip Overvoltage, Undervoltage, Overcurrent, Drive overtemperature, Motor overtemperature, I/O phase loss, I/O mis-wiring, Overload , External device fault 1.2, Loss of speed command, Hardware fault, Communication error, CPU error
Drive alarm Stall prevention, Overload alarm
Momentary power loss Less than 15 msec: keeping operation
More than 15 msec: auto restart available
Display Keypad Operation information Output frequency, current and voltage, Set frequency value, Operation speed, DC voltage
Trip information Display the trip cause when the protection function activates. Recent 5 faults records stored
Environment Ambient temperature -10 ~ 40℃
Storage temperature -20 ~ 65℃
Humidity 90 %RH max (No condensing)
Atmosphere No corrosive gas, flammable gas, oil mist or dust
Pressure 70 ~ 106k Pa

More Information

All in one

Hanoi Office

10th floor, 789 building, 147 Hoang Quoc Viet street, Cau Giay District, Ha Noi city, Vietnam

Hai Phong

LGE Factory - Tràng Duệ Industrial - An Dương District, Hải Phòng City

Da Nang

Văn phòng đối tác (HVN) 305 - Nguyễn Tất Thành - Hải Châu - Đà Nẵng

Ho Chi Minh Office

17th floor, Empress building, 138-142 Hai Ba Trung street, Da Kao ward, Distric 1, Ho Chi Minh city, Vietnam

Log in

Welcome to LS Electric