| Main Supply | Main Voltage (L1, L2, L3)
- SSC□-□□□-V4
- SSC□-□□□-V6 | 200~440VAC (+10/-15%)
200~575VAC (+10/-15%) |
|---|
| Main Frequency (at start) | 45 to 66 Hz |
| Rated Insulation Voltage | 600VAC |
| Form Designation | Bypassed, Semiconductor Motor Starter form 1 |
| Control Voltage
(A1, A2, A3) | SSC□-□□□-□□-C1 | 110~240VAC (+10%/-15%) |
|---|
| SSC□-□□□-□□-C1 | 380~440VAC (+10%/-15%) |
| SSC□-□□□-□□-C2 | 24VAC/VDC((±20%) |
| Current Consumption (During Run) | < 100mA |
| Current Consumption (Inrush)
- SSC□-□□□-□□-C1
- SSC□-□□□-□□-C2 | 10A
2A |
| Inputs | Start (Terminal 01) | Normally open (150kΩ@300VAC and 5.6kΩ@24VAC/VDC) |
|---|
| Stop (Terminal 02) | Normally Closed (150kΩ@300VAC and 5.6kΩ@24VAC/VDC) |
| Outputs | Main Contactor
(Terminals 13,14) | Normally Open (6A, 30VDC / 6A, 250VAC Resistive) |
|---|
| Programmable Relay
(Terminals 23,24) | Normally Open (6A, 30VDC / 6A, 250VAC Resistive) |
| Environmental | Degree of Protection
SSC□-018 to SSC□-060 | IP20 |
|---|
| Degree of Protection
SSC□-075 to SSC□-200 | IP00 |
| Operating Temperature | -10°C to +60°C |
| Storage Temperature | -25°C~60°C (to +70°C for Less than 24 Hours) |
| Humidity | 5%~95% Relative Humidity |
| Pollution Degree | Pollution Degree 3 |
| Vibration | IEC 60068 Test Fc Sinusoidal
4Hz to 13.2Hz : ±1mm Displacement
13.2Hz to 200Hz : ±0.7g |
| EMC Emission | Equipment Class (EMC) | Class B |
|---|
| Conducted Radio Frequency Emission | 0.15MHz to 0.5MHZ: <56~46dB (uV)
0.5MHz to 5MHz: <46dB (uV)
5MHz to 30MHz: <50dB (uV) |
| Radiated Radio Frequency Emission | 30MHz to 230MHz: <30dB (uV) |
| EEMC Immunity | Electrostatic Discharge | 4kV Contact, 8kV are Discharge |
|---|
| Radio Frequency Electromagnetic Field | 0.15MHz to 1000MHz: 140dB(uV) |
| Rated Impulse Withstand Voltage (Fast
Transients 5/50ns) | 2kV Line to Earth, 1kV Line to Line |
| Voltage Dip and Short Time Interruption | 100ms (at 40% Nominal Voltage) |
| Harmonics and Distortion | IEC 61000-2-4 (Class 3), EN/IEC61800-3 |
| Short Circuit | Rated Short-circuit Current SSC□-018 to 060 | 5KA* |
|---|
| Rated Short-circuit Current SSC□-075 to 200 | 10KA* |
| Heat Dissipation | During Start | 3 watts / Ampere |
|---|
| During Run | 10 Watts Typical |
| Operational Life | SSC□-018 to 060 | 1,000,000 Operations |
|---|
| SSC□-075 to 200 | 30,000 Operations |